Re: [BLAST_TOF] end of shift

From: Tancredi Botto (tancredi@mitlns.mit.edu)
Date: Mon Sep 09 2002 - 01:56:24 EDT


regarding this problem,
couldn't you just connect a BNC "T" connector on your small
paddle and have both the Top and Bot signal start from
there ? (self coinc)

-- tancredi

________________________________________________________________________________
Tancredi Botto, phone: +1-617-253-9204 mobile: +1-978-490-4124
research scientist MIT/Bates, 21 Manning Av Middleton MA, 01949
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^

On Fri, 6 Sep 2002, Adrian T Sindile wrote:

> Hi, John!
> In the early afternoon I had to drop off a friend at the airport, so I
> could not answer right away, sorry.
> About the bottom PMTs being used, I was only pointing out a problem, I did
> not have a solution.
> I came to Bates on Pete's evening shift and we started fanning out the
> bottom signals, so that that signal goes to both top and bottom. This will
> solve our problem, the only thing is there might not be enough cables and
> connectors around...
> Anyway, Pete will try and finish the cabling and maybe work some more on
> the CODA problem tonight (Karen needs to return a call).
> I will be back on the Sunday evening shift, Tavi is on shift overnight.
>
> Adrian
>
> -------------------------------
> Adrian Sindile
> Research Assistant
> Nuclear Physics Group
> University of New Hampshire
> phone: (603)862-1691
> FAX: (603)862-2998
> email: asindile@alberti.unh.edu
> http://einstein.unh.edu/~adrian/
>
>
>



This archive was generated by hypermail 2.1.2 : Mon Feb 24 2014 - 14:07:28 EST