[BLAST_SHIFTS] Shift summary

From: Electronic Log Book (elog@blast05.lns.mit.edu)
Date: Sun Jul 20 2003 - 08:02:25 EDT


Operators: tsentalovich karpiusp ----

  Half of the shift was used to rejuvinate ABS. NEGs have been fired, and the nozzle refreezed. Resumed data taking at about 5 am.
  WC L6 kept tripping, so we reduced the voltage from 3700 to 3600. No trips after that.
  File crunching was done and RUNLIST was updated.