Operator: tancredi
Worth noting only that HV can get stuck at "restore in progress" at which
point you are not taking data. Action is
a) end the run to avoid problems with beam gate
b) reboot the IOC (./BOOT on dtun1-pc)
and then more of the same. Continue production on pol D. Next scheduled access is tuesday (wc gas, abs nozzle and snake fill)