TOF L15 not firing Re: [BLAST_SHIFTS] Shift summary 03/13/2005 B (9-17)

From: Chi Zhang (zhangchi@MIT.EDU)
Date: Sun Mar 13 2005 - 17:16:53 EST


left TOF 15 does not seem to be triggering. this can be confirmed by
loading any lr file and say

lr->Draw("ntl", "ntl>-1")

this can explain the low yield in e'p. this also knocks out most stat for
ed elastic in parallel kinematics. perpendicular kinematics has tiny
asymmetry at low Q2, so this precludes Pzz measurement with the runs taken
so far.

Chi

On Sun, 13 Mar 2005, Electronic Log Book wrote:

> Operator: vziskin
>
> The shift started with 100 mA injected beam. The polarization appears to remain low as noted by Michael. At 14:30 we went to a higher injection current (150 mA) per Genya's agreement. The target holder temperature sensors are show high temperature and currently off scale. At the same time the cold head and the cell temperatures show little difference. When we went to higher current the temperature PID control went berserk and I turned it off since it really does not do anything. The ligit, which was dropping slowly before the injection current increase, has jumped and once in a while shows large vacuum excursions. However, the beam appears to be well behaved with low BQMs, scaler rates and high lifetime.
>
>
>
>



This archive was generated by hypermail 2.1.2 : Mon Feb 24 2014 - 14:07:32 EST