[BLAST_SHIFTS] Shift summary 03/29/2005 C (17-1)

From: Electronic Log Book (elog@blast05.lns.mit.edu)
Date: Wed Mar 30 2005 - 01:02:12 EST


Operator: karpiusp

Many WC trips on L21 sense and guard wire. This was not bad at start of shift but increased over time. During RUN 14761 reduced L21 to max voltage it would hold for more than a few minutes - this was 3700V. Thinking that this was too low I asked CCR if they could lower the injection from 210mA to 200mA to mitigate ion buildup. During the following run I was able to raise L21 to 3800V where it stayed for the remainder of the shift. - perhaps ready to try 3850V

Noticed that tclr0 seemed to be dominated by self-timing events but this dissipated over a few hours - no idea why

Took ABS RUNS:14579-14760 (L21 at 3850V)
14761 (L21 at 3700V)
14762-14765 (L21 at 3800V)

VPol results for 3/28/05 C shift(latest crunched): 3.16 kC
L: 0.519+-0.062 R:0.549+-0.042



This archive was generated by hypermail 2.1.2 : Mon Feb 24 2014 - 14:07:32 EST