As of 16:30 7/12/02:
Flaky PMTs/cables/voltage dividers in the LTOF system have been
identified and are being fixed/replaced.
Overnight several runs were taken which were ostensibly the
requested (retiming_OR - start_mean). Howver the signal plugged
into TDC32 was NOT the retiming_OR out of the level adapter
but instead was the the output of the XMLU which also went
through the same level adapter but was 2 sets of pins away in
the ribbon connector. That has been remedied.
*** If you disconnect something, you must be careful when you
replace it!! ***
The plan for the night of 7/12 is to redo last night's running
but now with the correct input. The trigger settings in the
MLUs should be the same as last night. Kevin has a root script
for analyzing the data in :
/home/blast/blast/commis/phase1/ANALYSES/MCILHANY/retimingORX.C
-- John R. Calarco Dept. of Physics Univ. of New Hampshire Durham, NH 03824 phone: (603)862-2088 FAX: (603)862-2998 email: calarco@unh.edu