Operators: tavi ---- ----
The following are the new HV values for the middle size CC's:
LCC1_T_0 = -2565 RCC1_T_0 = -2525
LCC1_T_1 = -2333 RCC1_T_1 = -2655
LCC1_T_2 = -2415 RCC1_T_2 = -2078
LCC1_T_3 = -2611 RCC1_T_3 = -2299
LCC1_B_0 = -2389 RCC1_B_0 = -2349
LCC1_B_1 = -2600 RCC1_B_1 = -2219
LCC1_B_2 = -2223 RCC1_B_2 = -1965
LCC1_B_3 = -2273 RCC1_B_3 = -2475
A while ago we discovered a bad channel that caused the right crate to trip, namely: crate#1_slot#6_channel#8 (RCC1_B_2 = -1965V) and we moved it to
crate#1_slot#6_channel#5, Jason sent that message at that time! But this was not updated in the HVGui. Right now the SHV cabe (#23) is back in channel#8, but if the crate trips then it should be moved to channel#5. Please pay attention to these messages, we have not use a CC's good tube for a month (i.e. in RCC1 box). For any other CC's detail, see the CC's logbook.