Hi, Michael, Adam!
I included the LADS into the MySQL database, as promised.
The high voltage table for them is LAD_HV.

I also gave all necessary permissions to user "HVGUI" to do whatever it
needs - so Adam's GUI should have no problem writing to the new table.
Please check it out and let me know if there are any problems...

Adrian

-------------------------------
Adrian Sindile
Research Assistant
Nuclear Physics Group
University of New Hampshire
phone: (603)862-1691
FAX: (603)862-2998
email: asindile@alberti.unh.edu
http://einstein.unh.edu/~adrian/

On Sat, 13 Sep 2003, Adrian T Sindile wrote:

> Hi, Michael!
> Sure, no problem - I will add the LADS into the MySQL database.
> I think I can have them ready by Tuesday night. Hope this is OK (I might
> have them earlier, but just to be on the safe side).
> I will contact you if I have questions about naming conventions etc.
>
> Please note my email address is asindile@hopper.unh.edu, NOT adrian@...
> Thank you!
>
> Adrian
>
> On Fri, 12 Sep 2003, Michael Kohl wrote:
>
> > Hi Adam and Adrian,
> >
> > the LADS walls are now completely cabled with HV and were attached to the
> > HV crates in the Dtunnel.
> > Please find attached a table with the requested information of the
> > stby and oper voltages, the trip current, and ramping speed.
> >
> > Doug and I have also set up shellscripts based on the previous wire
> > chamber hv scripts, named LADSHVL and LADSHVR (in pro2003/hv)
> >
> > The voltages and the trip current need to be negative.
> >
> > As the values are overwritten by the ring fill software after each refill,
> > and the "save" button in the Epics GUI is only god for one life cycle of
> > the IOC, I can't really set the LADS voltages and keep them up safely for
> > the rest of the weekend.
> >
> > >From running the scripts we noticed that there is no trip at the standby
> > values, however at the oper values the crates did indicate tripoffs.
> > I the tripoffs at the oper values persist, I would recommend to condition
> > the LADS walls at standby values of 700 V each channel, until this is
> > further investigated.
> >
> > I would appreciate very much if you Adam and Adrian could take care of the
> > implementation into Epics and into the database as soon as possible.
> >
> >
> > Thanks and a good weekend,
> >
> >
> > Michael
> >
> >
> >
> >
> >
> > On Thu, 11 Sep 2003, Adam Jon DeGrush wrote:
> >
> > > Hi Michael,
> > >
> > > I need the following for information each channel.
> > >
> > > Channel Name | Crate # | Slot # | Channel Number | Run Voltage (V)|
> > > Standby Voltage (V)| Trip Current (uA)
> > >
> > > Adrian is in charge of the mysql database so he will add them in to the
> > > BLAST database.
> > >
> > > As soon as you give me the info, I can start working on it but it will
> > > probably take the weekend to finish since there is a lot of code for each
> > > detector sub-group added.
> > > Cheers,
> > > Adam
> > >
> > >
> > > On Thu, 11 Sep 2003, Michael Kohl wrote:
> > >
> > > > Hi Adam,
> > > >
> > > > yesterday we completed the installation of the LADS neutron counters in
> > > > the hall. Today I will finish up the HV cabeling in the Dtunnel.
> > > >
> > > > In order to operate the HV as soon as possible, I'd like to ask you if you
> > > > could take care of the implementation into Epics, i.e. into the database
> > > > (I already have individual values to initialize the phototubes) and into
> > > > the GUI. I would like to condition the phototubes over the weekend, such
> > > > that we have a stable system by Monday which we can further set up
> > > > (the electronics) next week.
> > > >
> > > > I could use the dumb terminal to set the voltages, however once there is a
> > > > reboot or reload from the database, the LADS channels would get zeroed
> > > > again.
> > > >
> > > > Please contact me at Bates (number below), and let me know what you need
> > > > from me.
> > > >
> > > >
> > > > Thanks and regards,
> > > >
> > > > Michael
> > > >
> > > >
> > > >
> > > > --
> > > >
> > > > +-------------------------------------+--------------------------+
> > > > | Office: | Home: |
> > > > |-------------------------------------|--------------------------|
> > > > | Dr. Michael Kohl | Michael Kohl |
> > > > | Laboratory for Nuclear Science | 5 Ibbetson Street |
> > > > | MIT-Bates Linear Accelerator Center | Somerville, MA 02143 |
> > > > | Middleton, MA 01949 | U.S.A. |
> > > > | U.S.A. | |
> > > > | - - - - - - - - - - - - | - - - - - - - - -|
> > > > | Email: kohlm@mit.edu | K.Michael.Kohl@gmx.de |
> > > > | Work: +1-617-253-9207 | Home: +1-617-629-3147 |
> > > > | Fax: +1-617-253-9599 | Mobile: +1-978-580-4190 |
> > > > | http://blast.lns.mit.edu | |
> > > > +-------------------------------------+--------------------------+
> > > >
> > > >
> > > >
> > > >
> > > >
> > > >
> > > >
> > > >
> > > >
> > > >
> > > >
> > > >
> > > >
> > > >
> > > >
> > > >
> > >
> >
> > --
> >
> > +-------------------------------------+--------------------------+
> > | Office: | Home: |
> > |-------------------------------------|--------------------------|
> > | Dr. Michael Kohl | Michael Kohl |
> > | Laboratory for Nuclear Science | 5 Ibbetson Street |
> > | MIT-Bates Linear Accelerator Center | Somerville, MA 02143 |