Re: [BLAST_SHIFTS] Shift summary 03/23/2004 D (12-16)

From: Adam Jon DeGrush (degrush@MIT.EDU)
Date: Tue Mar 23 2004 - 17:06:38 EST


Just so people know and although I haven't checked it in a while so
anything is possible, there is a button that reinitialized the crates
from the database through the hvgui. This circumvents having to reboot
the crates. It is the first button in the General Control Window.

Adam

On Tue, 23 Mar 2004, Adrian T Sindile wrote:

> Hi!
> LTOF9 bottom was reported as counting low. I just increased the voltage on
> it by 40 volts, from -2260 to -2300V (well, "decreased" would be a better
> word). If this brings it to the neighbors' level, I will leave it like
> that.
>
> Could people on shift please restart the HVGUI, so that the voltages are
> reinitialized from the database?
> Thank you!
>
> Adrian
>
> -------------------------------
> Adrian Sindile
> Research Assistant
> Nuclear Physics Group
> University of New Hampshire
> phone: (603)862-1691
> FAX: (603)862-2998
> email: asindile@alberti.unh.edu
> http://einstein.unh.edu/~adrian/
>
>
>



This archive was generated by hypermail 2.1.2 : Mon Feb 24 2014 - 14:07:30 EST