[BLAST_ANAWARE] blast.sc_cal changed

From: Michael Kohl (kohlm@mit.edu)
Date: Sat Jul 10 2004 - 10:40:33 EDT


Hi,

After gaining enough confidence, I have changed blast.sc_cal in
~blast/pro2004/Blast_Params and in cvs to provide better timing for
neutron counters.
As I wrote last Tuesday, I tested the old and new calibration file on run
8565 and find only improvements for ttl-ttr (trig==1) and for
tnn (trig==2).

TDC offsets were determined as follows:

TOF timing as from PKs flasher analysis of run 7150
NC,LADS timing as from cosmics analysis of run 7150, based on above TOF
offsets.
NC,LADS are walk corrected.

I take the opportunity of the power failure to introduce this change also
for the online crunching, affecting runs >=8731.

Note that TOF timing will slightly change, and also beta for protons and
deuterons.

Regards,

  Michael

-- 

+-------------------------------------+--------------------------+ | Office: | Home: | |-------------------------------------|--------------------------| | Dr. Michael Kohl | Michael Kohl | | Laboratory for Nuclear Science | 5 Ibbetson Street | | MIT-Bates Linear Accelerator Center | Somerville, MA 02143 | | Middleton, MA 01949 | U.S.A. | | U.S.A. | | | - - - - - - - - - - - - | - - - - - - - - -| | Email: kohlm@mit.edu | K.Michael.Kohl@gmx.de | | Work: +1-617-253-9207 | Home: +1-617-629-3147 | | Fax: +1-617-253-9599 | Mobile: +1-978-580-4190 | | http://blast.lns.mit.edu | | +-------------------------------------+--------------------------+