Re: [BLAST_ANAWARE] k-factor, theta correction and resolution

From: Chi Zhang (zhangchi@MIT.EDU)
Date: Fri Aug 27 2004 - 17:30:08 EDT


Not yet.

On Fri, 27 Aug 2004, Wang Xu wrote:

> Hi Chi,
> Did we recrunch all data with these new k-factor & theta
> correction?
> Wang
>
> On Thu, 26 Aug 2004, Chi Zhang wrote:
>
> >
> > Hi,
> >
> > I found the following interesting thing about wire chamber calibration
> > and resolution.
> >
> > With k-factors revived, AND theta correction activated. We in fact are
> > looking at improved resolutions. The comparison with current setup for
> > online crunching is:
> >
> > current improved
> > k-factor only for tracks with beta<0.9 for all
> > theta correction not used used
> >
> > I believe the "improved" calibration has also the advantage of being
> > easier to retionalize than the current approach which treats slow and fast
> > tracks differently.
> >
> > Some more details including the fact that k-factors calibrated in Feburary
> > do not really fit data since May. I have made a new set of k-factor
> > calibration based on a score of July runs and they seem to improve
> > resolution for June/July/Aug H2 runs.
> >
> > I list results here for some H2 runs I can find:
> > dP_e dtheta dphi dz dP_p dE_beam
> > 6451-6452 (Apr 10): 21 0.50 0.63 1.0cm 22 28
> > 21 0.53 22 27
> >
> > 6992( Apr 23): 24 0.51 0.59 1.0cm 20 28
> > 19 0.48 23 29
> >
> > 8372-8375 (Jun 20): 27 0.54 0.64 1.2cm 24 33
> > 24 0.56 23 29
> >
> > 8868-8870 (Jul 23): 30 0.63 0.65 1.5cm 29 41
> > 28 0.61 28 38
> >
> > 9854-9864 (Aug 08): 28 0.58 0.65 1.3cm 28 34
> > 27 0.57 21 35
> >
> > For these runs, the April ones are crunched with k-factors calibrated in
> > Feb (Wire.Cal v1.6). The rest are crunched with k-factors newly calibrated
> > off July runs.
> >
> > angular resolutions are improved from the >~1 degree level we currently
> > have. electron momentum resolution is also improved and is comparable to
> > the best we have ever seen in past. vertex resolution is also improved to
> > 1cm level from the 1.5-2cm we had. Proton resolution is still a bit worse
> > than the 15MeV we had according to Chris. I believe these figures overall
> > are an improvement.
> >
> > I believe with more work devoted into calibrations(Eugine, Chris,
> > Taylan and me) it is very likely the resolutions would improve on top of
> > this level.
> >
> > I also want to point out that we did not have ANY H2 runs for the entire
> > May. So it is a little hard to determine how the calibration worked for
> > that period of time.
> >
> > I would like to repeat the observation made in one of the "big" analysis
> > meeting last summer, when I presented the change in time of WC resolution,
> > periodically running H2 is necessary. Unfortunately, we were very deep in
> > the deuterium data rush.
> >
> > In the end, recrunch from DST using this new set of "calibration" will
> > give us the improved resolution.
> >
> > Chi
> >
>
>