Re: [BLAST_SHIFTS] Shift summary 04/13/2005 B (9-17)

From: Chi Zhang (zhangchi@MIT.EDU)
Date: Wed Apr 13 2005 - 19:58:33 EDT


Hi, compared new and old, see the plot attatched. took me a while to
realize that the new calib converts to Amp, not mA as the old one. bottum
is the calibration, top figure is the relative difference between the two.

forget about line 46 and 54, they are there in case the epics.cal file can
not be opened. I ll take care of TBLEpicsRecon.cc.

Chi

On Wed, 13 Apr 2005, Chris Crawford wrote:

> ah yes. ... (down to 1/4, not much of a surprise at all)
> TBLEpicsRecon.h:146: float par0, par1, par2, pedestal;
> TBLEpicsRecon.cc:46: pedestal = 4800;
> TBLEpicsRecon.cc:54: pedestal = 2400;
> TBLEpicsRecon.cc:77:
> >>inputreg>>tslreg>>slots>>nbgsca>>bgsca>>spinflipon>>pedestal>>par0>>par1>>par2;
> TBLEpicsRecon.cc:85:
> >>inputreg>>tslreg>>slots>>nbgsca>>bgsca>>spinflipon>>pedestal>>par0>>par1>>par2;
> TBLEpicsRecon.cc:440: scal_charge = raw.scalers[nbgsca+slots*9].value -
> pedestal;
> TBLEpicsRecon.cc:443: bgscal_charge = raw.scalers[bgsca+slots*9].value
> - pedestal*livetime;
>
> you can get away with just changing it to 0 in epics.cal (with the
> appropriate run number), since the calibration is read from this file.
> that way you don't have to hardcode in another if..then block . (same
> for other parameters)
> --Chris
>
> Douglas Hasell wrote:
>
> > Thanks Chris but obviously since the previous calibration had a
> > pedestal there should also be some lines to the effect of
> >
> > scal_charge = dcct - pedestal
> >
> >
> > Cheers,
> >
> > Douglas
> >
> > 26-415
> > M.I.T. Tel:
> > +1 (617) 258-7199
> > 77 Massachusetts Avenue Fax: +1
> > (617) 258-5440
> > Cambridge, MA 02139, USA E-mail:
> > hasell@mit.edu
> > On Apr 13, 2005, at 6:49 PM, Chris Crawford wrote:
> >
> >> Doug, ready for 1/3 of a pleasant surprise?
> >>
> >> There are 1/(1/3) places:
> >>
> >> ep_skim.h:128:float par0 = 2.90027; -> not used! delete it to save
> >> confusion
> >>
> >> TBLEpicsRecon.h:146: float par0, par1, par2, pedestal;
> >> TBLEpicsRecon.cc:47: par0 = 2.63549; par1 = 1.50749e-4; par2 =
> >> 1.8612e-10;
> >> TBLEpicsRecon.cc:55: par0 = 2.90027, par1 = 3.01409e-4, par2 =
> >> 6.18094e-10;
> >> TBLEpicsRecon.cc:77:
> >> >>inputreg>>tslreg>>slots>>nbgsca>>bgsca>>spinflipon>>pedestal>>par0>>p
> >> ar1>>par2;
> >> TBLEpicsRecon.cc:85:
> >> >>inputreg>>tslreg>>slots>>nbgsca>>bgsca>>spinflipon>>pedestal>>par0>>p
> >> ar1>>par2;
> >> TBLEpicsRecon.cc:446: fScaler->fScaler_Beam = par0 +
> >> scal_charge*(par1 + par2*scal_charge);
> >> TBLEpicsRecon.cc:447: fScaler->fBG_Beam = par0 +
> >> bgscal_charge*(par1 + par2*bgscal_charge);
> >>
> >> and then edit "Blast_Param/epics.cal"
> >> note: this file is not archived (it has its own history), so don't
> >> worry about reading a file with fewer parameters. good design
> >> choice, Chi!
> >>
> >> i don't care about when you start crunching with the update, but
> >> please check in a new version of BlastLib2 (v3_4_7) when you do.
> >> (see elog sticky note)
> >>
> >> --Chris
> >>
> >>
> >> Douglas Hasell wrote:
> >>
> >>> Did not ask Dan about this. We can check when we get beam.
> >>>
> >>> Who knows where all the places for this calibration exist in the
> >>> code. I will be pleasantly surprised it there is just one place
> >>> that needs to be changed. Also we need to decide when we change
> >>> the code.
> >>>
> >>>
> >>> Cheers,
> >>>
> >>> Douglas
> >>>
> >>> 26-415
> >>> M.I.T.
> >>> Tel: +1 (617) 258-7199
> >>> 77 Massachusetts Avenue Fax: +1
> >>> (617) 258-5440
> >>> Cambridge, MA 02139, USA E-mail:
> >>> hasell@mit.edu
> >>> On Apr 13, 2005, at 6:07 PM, Chris Crawford wrote:
> >>>
> >>>> Hi Doug,
> >>>> Was the calibration of the epics LDCCT variable OK? I was under
> >>>> the impression that Dan had been calibrating it periodically in
> >>>> hardware, so it should still be accurate.
> >>>> --thanks, Chris
> >>>>
> >>>> Electronic Log Book wrote:
> >>>>
> >>>>> Operator: hasell
> >>>>>
> >>>>> Easy shift - hall open.
> >>>>>
> >>>>> Karen, Dan, and I recalibrated the DCCT scaler against a
> >>>>> calibrated charge source. See run 15198. Also performed the
> >>>>> fit. Results are in ELOG. Interesting thing to note is that the
> >>>>> voltage to frequency converter is only good to just over 250 mA
> >>>>> so unless we want to make a big change we should stay below 250
> >>>>> mA for data acquisition.
> >>>>>
> >>>>> Michael and Karen replaced the laser on the flasher system. So
> >>>>> that is working again for runs 15206 and following.
> >>>>>
> >>>>> Aki has recalibrated the unpol system so it is now available for
> >>>>> both H and D.
> >>>>>
> >>>>> Nozzle was regenerated and Genya started ABS again.
> >>>>>
> >>>>> Bill and Taylan measured the circular polarisation of the laser
> >>>>> just before it entered the ring and found that it is getting
> >>>>> worse with time. Mostlikely the reason is dirty optics. Still
> >>>>> the effect is small enough that we won't do anything about it.
> >>>>>
> >>>>> Other that we took cosmic data.
> >>>>>
> >>>>> Started locking up the south hall at 16:30.
> >>>>>
> >>>>> Runs 15200-15201 15203-15209 are cosmic
> >>>>>
> >>>>>
> >>>>
> >>
>
>