Re: [BLAST_SHIFTS] Daily BLAST meeting

From: Michael Kohl (kohlm@mit.edu)
Date: Tue May 03 2005 - 16:11:40 EDT


Hi Taylan,

when we ran staright tracks last time, we suffered greatly from not having
a suitable trigger and/or proper high prescaling factors of all other
triggers besides PHYS0. I'm not sure if this is available now.

For simplicity I would recommend the same trigger setting but to use Coda
readout lists with high prescale factors for PHYS1-6. Let me know if you
need help.

Regards,

  Michael

 On Tue, 3 May 2005, Taylan Akdogan wrote:

>
>
> - The detector is closed
> - Blast and holding fields are off
> - The hall is closed
>
> There will be a short controlled access for an undergraduate
> tour.
>
> The beam will be tuned for field-off state. We'll use unpol
> hydrogen with fields off for the calibration data overnight.
> Getting the maximum current is not critical, so we'll take
> whatever the current we can get (50-100mA should be fine.)
>
> Compton will use this time to check the systematic effects of the
> absorber. The thickness of the absorber will be changed
> automatically every other fill. This should not effect any other
> component of the blast and/or beam.
>
> Taylan
>
>

-- 

+-------------------------------------+--------------------------+ | Office: | Home: | |-------------------------------------|--------------------------| | Dr. Michael Kohl | Michael Kohl | | Laboratory for Nuclear Science | 5 Ibbetson Street | | MIT-Bates Linear Accelerator Center | Somerville, MA 02143 | | Middleton, MA 01949 | U.S.A. | | U.S.A. | | | - - - - - - - - - - - - | - - - - - - - - -| | Email: kohlm@mit.edu | K.Michael.Kohl@gmx.de | | Work: +1-617-253-9207 | Home: +1-617-629-3147 | | Fax: +1-617-253-9599 | Mobile: +1-978-580-4190 | | http://blast.lns.mit.edu | | +-------------------------------------+--------------------------+



This archive was generated by hypermail 2.1.2 : Mon Feb 24 2014 - 14:07:32 EST